    120kva Outdoor UPS Battery Backup 1 Hours , Industrial Lowe Frequency Ups System

    Ask Lasest Price
    Brand Name : CPSY
    Model Number : GP33120K
    Certification : CE, TLC
    Price : USD/PCS
    Payment Terms : T/T, Western Union
    Delivery Time : 25-35days
    • Product Details
    • Company Profile

    120kva Outdoor UPS Battery Backup 1 Hours , Industrial Lowe Frequency Ups System

    120kva ups power solution backup 1hours, industrial ups system


    Low Frequency Online UPS

    Technical Specifications

    True Online Dual Conversion UPS

    Built-in Galvanic Isolation Transformer

    Field Proven Rugged design for tough power conditions

    State of the art technology

    IGBT based SPWM technology

    Excellent warranty & post warranty support

    Wide range of products from 1KVA to 300KVA

    Wide input range

    Compact size

    High performance/High efficient design

    Near unity input power factor

    Excellent Voltage Regulation and Transient response

    User friendly comprehensive LCD display and mimic diagram

    Supports all types of batteries

    Extended Run Time

    Generator Compatible

    After Sale support available in major cities across the country

    Optional Intelligent Computer Interface and SNMP

    Optional Auto Bypass (Static bypass)

    Optional Parallel redundancy / Static redundancy


    Applications

    Office Automation

    Data Centres

    Building Management

    Education Institutes

    Telecommunication Centres

    Satellite Earth Station

    CNC Machines

    Banking

    Defence

    R and D Centres

    Bio-medical Equipments

    Lift and Elevators

    Industrial Instrumentation

    Machine Tools

    Security and surveillance equipments

    Colour Lab Equipment

    Photo Copying Machines

    Printers and Plotters

    Embroidery Machines

    Medical Equipments

    Diagnostic/Lab Equipments

    Ultra Sonic Sonography Machines

    ATM Centres


    Parameter:

    Model GP3360K GP3380K GP33100K GP33120K GP33160K GP33200K
    Capacity 60KVA/48KW 80KVA/72KW 100KVA/80KW 120KVA/96KW 160KVA/128KW 200KVA/160KW
    INPUT
    Norminal Voltage 3*380VAC/400VAC(3PH +N)
    Acceptable voltage range 285VAC~475VAC
    Frequency Range 50Hz/60Hz±10%
    INVERTER
    Norminal voltage 380V
    Precision 380V±25%
    Frequency 50Hz/60Hz
    Waveform Pure Sine wave
    Total Harmonic Distortion(THDv) ≤2% (linear load); ≤5% (non-linear load)
    Phase Displacement 120°±1%(balanced load); 120°±2%(imbalances 50% of the load)
    Dynamic Recovery Time 3 cycles at 90% of the static value
    Admissible Overload 110% for 10min;150% for 60sec;>160% for 200ms
    AdmissibleCrest Factor 3:01
    Admissible Power factor 0.6~1(inductive or capacitive)
    Imbalance output voltage@100% unbalanced load <1%

    Current limit High overload, short circuit, RMS voltage limit, High Crest-factor Curren, Peak voltage limit
    STATIC BYPASS
    Type Solid state
    Voltage 3*380VAC/400VAC(3PH +N)
    Frequency 50Hz/60Hz
    Activation Criterion Microprocessor control
    Transfer time Zero
    Admissible Overload 150% for 1hour;180% for 30sec;>200% for 200ms
    Transfer to Bypass Immediate, for overload above160%
    Retransfer Automatic after alarm clear
    MAINTENANCE BYPASS
    Type Without Interruption
    Voltage 3*400V(3PH+n)
    Frequency 50Hz/60Hz
    Overall Efficiency(line mode) Line mode 105%±5% ≤load,warning overload;
    Battery Mode 105%±5% <load≤125%±5% Transfer to bypass and Alarming after 2 mins;
    BATTERY & CHARGE
    Battery type & Number 12VDC*32pcs(29~32pcs adjustable)
    Normal Battery Voltage 384VDC(Based on 32pcs batteries)
    Charging Method CC/CV
    Charging Current Default 10A, Max.=capacity(KW)/battery voltage(real time) Default: 10A.Max.40A;5A@full load
    Charging Voltage 432VDC(Based on 32pcs batteries)
    Safety requirements GB4943-2001/IEC62040-1 EMC/EMI, IEC 61000-4-5 Protection surge
    Noise(1m) ≤55dB
    PHYSICAL
    Dimension,D×W×H (mm) 821x432x1159 975×554×1286 975×554×1326 1051×705×1646
    Net Weight(KGS) 365 471 573 650 760 840


    ModelGP33120KGP33160KGP33200K
    Capacity120KVA/96KW160KVA/128KW200KVA/160KW
    INPUT
    Norminal Voltage3*380VAC/400VAC(3PH +N)
    Acceptable voltage range285VAC~475VAC
    Frequency Range50Hz/60Hz±10%
    INVERTER
    Norminal voltage380V
    Precision380V±25%
    Frequency50Hz/60Hz
    WaveformPure Sine wave
    Total Harmonic Distortion(THDv)≤2% (linear load); ≤5% (non-linear load)
    Phase Displacement120°±1%(balanced load); 120°±2%(imbalances 50% of the load)
    Dynamic Recovery Time3 cycles at 90% of the static value
    Admissible Overload110% for 10min;150% for 60sec;>160% for 200ms
    AdmissibleCrest Factor0.125694444
    Admissible Power factor0.6~1(inductive or capacitive)

    Imbalance output voltage

    @100% unbalanced load

    <1%
    Current limitHigh overload, short circuit, RMS voltage limit, High Crest-factor Curren, Peak voltage limit
    STATIC BYPASS
    TypeSolid state
    Voltage3*380VAC/400VAC(3PH +N)
    Frequency50Hz/60Hz
    Activation CriterionMicroprocessor control
    Transfer timeZero
    Admissible Overload150% for 1hour;180% for 30sec;>200% for 200ms
    Transfer to BypassImmediate, for overload above160%
    RetransferAutomatic after alarm clear
    MAINTENANCE BYPASS
    TypeWithout Interruption
    Voltage3*400V(3PH+n)
    Frequency50Hz/60Hz
    Overall Efficiency(line mode)Line mode105%±5% ≤load,warning overload;
    Battery Mode105%±5% <load≤125%±5% Transfer to bypass and Alarming after 2 mins;
    BATTERY & CHARGE
    Battery type & Number12VDC*32pcs(29~32pcs adjustable)
    Normal Battery Voltage384VDC(Based on 32pcs batteries)
    Charging MethodCC/CV
    Charging CurrentDefault 10A, Max.40A;5A@ full load
    Charging Voltage432VDC(Based on 32pcs batteries)
    Safety requirementsGB4943-2001/IEC62040-1 EMC/EMI, IEC 61000-4-5 Protection surge
    Noise(1m)≤55dB
    PHYSICAL
    Dimension,D×W×H (mm)975×554×13261051×705×1646
    Net Weight(KGS)650760840